INSULATING OIL TESTERS: CU SERIES FULLY AUTOMATIC

 
• Easy operation-Fully automatic test cycle along with average BDV display.
• Automatic change of sample number of test.
• Automatic calendar and time running even with power off.
• Recall and print last 99 test results stored for 100 years even with power off.
• Programmable: Number of tests, Settling time, stir time, and waiting time.
• LCD 128 x 68 mm displays: Test status, HV rise, HV fall, BDV of previous test
  and test results.
• Tests to: IEC 156, IS 6792, JIS C2101, BS 5874, VDE 0370, GB-86 etc.
• Countdown display of time in ‘Settling, Stir, and Waiting’ modes.
• Built in printer.
• Zero start safety and test chamber access interlock.
• Ergonomic design, completely user friendly-just 36 kg in weight.
 
Introduction:

Insulating oil being an efficient cooling medium with high dielectric strength has been a recognized insulating medium in electrical equipments. Degradation of oil takes place due to acids, oxidation, sludge, gas and water absorption. A dielectric strength test shows the changes caused in oil due to these processes. 'UDEY' Series CU insulating oil testers are fully automatic microcontroller based testers completely self contained with built in printer. 'UDEY' insulating oil testers are the industry standard for over 47 years.

System Description:

The system is fully automatic and carries out tests according to the set or chosen menu like ‘Number of tests, Settling time, Stir time and Waiting time’. System time, setting of test parameters, status and data is displayed on LCD. Audio beep is given after the test is complete and the results can be printed on built-in printer. The test results can be recalled for view after the test. Further the last 99 test readings can also be recalled and printed.
 
Technical Specifications:

Input Supply
220 ±10% Volts AC, 50 Hz, single phase.
Test Voltage Model: CU-80 (80 kV.) Model: CU-60 (60 kV.)
Capacity Model: CU-80:1.6 kVA. Model: CU-60: 1.2 kVA.
Wave form Distortion
< 3%.
Accuracy 3%
Time of Breakdown < 10 millisecond.
Rate of rise of voltage 2 kV per second ± 20%.
kV Indication Three Digit
Test number indication One Digit
User defined settings a) Calendar, sample number
B) Number of Tests Settable from 1 to 6 times.
c) Settling time Settable from 0-999 seconds.
d) Stirring time Settable from 0-999 seconds.
e) Waiting time Settable from 0-999 seconds.
Test cell with Electrodes
Type ‘OC-5’: 36 mm mushroom electrodes.
Type ‘OC-7’: 25 mm flat disc electrodes.
Type ‘OC-9’: 13 mm round electrodes.
 
Gap Gauge 2.5 mm
Printer Built in printer for printing results.
Construction In light weight aluminum cabinet with removable cover, lock and lifting handles.
Temperature Range 5 to 40º C.
Relative Humidity < 85% RH
Working Altitude < 1500 meters.
Dimensions and weight 38 x 37 x 37 cm. Net 36 kg. (Approximately)
Standard Accessories 1) Test cell type ‘OC-07’ 1 number.
2) Mains cord 1 number.
3) Paper roll 2 numbers.
4) Spare fuses 3 numbers.
5) Operating manual one number.
Optional Accessories Test cells: ‘OC-5’ or ‘OC-9’. Gap gauge: 2 mm