Primary Current Injection Test Set

Current Injection Testers

Primary Current Injection Test Set

Model : PCT Series

Udey PCT series comprises of two units: 1) a control unit and 2) a loading unit. Thus making the tester compact and portable. Four models are available with outputs from 250 A to 3000 A. The control unit offers a current output of 0-10 Volt at 50 Amp or 0-5 Volt at 100 Amp. Additionally, a separate voltage output of 0-250 V AC is available for testing voltage operated relays coils or checking the magnetization characteristics of current transformers.

Machine Feature

  • All outputs continuously variable.
  • Built – in crystal time base multi range DIGITAL TIMER.
  • True RMS digital metering of outputs.
  • Compact rugged design – Fully tropicalised.
  • Auto-switch off in all modes of operation.
  • All current outputs fully isolated and distortion free.
  • Suitable for testing thermal devices
  • All controls and metering centralized.

Machine Technical Specification

Model PCT-5 PCT-10 PCT-20 PCT-30
Supply 240 V AC, 50/60 HZ 240 V AC, 50/60 HZ 240 V AC, 50/60 HZ 240 V AC, 50/60 HZ
Power 2 kVA 4 kVA 6 kVA 6 kVA
Output Loading unit 500 A @ 0-4V
250 A @ 0-8 V
1000 A @ 0-4V
500 A @ 0-8V
2000 A @ 0-3V
1000 A @ 0-6V
3000 A @ 0-2 V
1500 A @ 0-4V
Output Control unit 100 A @ 0-5 V
50 A @ 0-10 V
0-250 V @ 8 A
100 A @ 0-5 V
50 A @ 0-10 V
0-250 V @ 15 A
100 A @ 0-5 V
50 A @ 0-10 V
0-250 V @ 15 A
100 A @ 0-5 V
50 A @ 0-10 V
0-250 V @ 15 A
  • RATING : 5 Minutes ON / 15 Minutes OFF. Continuous rating does not exceed 50% of the rated output.
  • METERING : 1) LED digital Ammeter, CT operated for current outputs.
    2) LED digital Voltmeter for voltage output.
    Accuracy : ± 1% ± 3 counts.
  • DIGITAL TIMER : 4 digit, solid state crystal base timer system. Multi range from .0001 to 9999 seconds.
    Accuracy : ± 0.5 % ± 2 counts
  • TIMER CONTROL CIRCUITS : The timer automatically starts when the output is initiated and automatically stops when the device under test operates.
  • START SIGNAL : Internal.
  • STOP SIGNAL : Via-either normally open or normally closed external contacts.
  • AUTO-CUT-OFF : Cuts off output on operation of device under test.
  • OPERATION : Circuit breaker in input, mains on indicator, contractor controlled push buttons for current output on or off, contact mode selector and reset switch.
    ‘SET/TEST’ switch to set up test current level.
  • CONSTRUCTION : Two piece unit. Sheet steel cabinets powder coated and with fold away lifting handles.
  • OPTIONAL ACCESSORIES : 1. Low inductance lead set.
    2. Precision grade (0.5%) Analogue meter with Current transformer.

Standard Accessories

  • Operating Manual.
  • 2 meter long 3 core mains cable.
  • 2 meter long inter-connecting cable.
+ Feature

Machine Feature

  • All outputs continuously variable.
  • Built – in crystal time base multi range DIGITAL TIMER.
  • True RMS digital metering of outputs.
  • Compact rugged design – Fully tropicalised.
  • Auto-switch off in all modes of operation.
  • All current outputs fully isolated and distortion free.
  • Suitable for testing thermal devices
  • All controls and metering centralized.
+ Technical Specification

Machine Technical Specification

Model PCT-5 PCT-10 PCT-20 PCT-30
Supply 240 V AC, 50/60 HZ 240 V AC, 50/60 HZ 240 V AC, 50/60 HZ 240 V AC, 50/60 HZ
Power 2 kVA 4 kVA 6 kVA 6 kVA
Output Loading unit 500 A @ 0-4V
250 A @ 0-8 V
1000 A @ 0-4V
500 A @ 0-8V
2000 A @ 0-3V
1000 A @ 0-6V
3000 A @ 0-2 V
1500 A @ 0-4V
Output Control unit 100 A @ 0-5 V
50 A @ 0-10 V
0-250 V @ 8 A
100 A @ 0-5 V
50 A @ 0-10 V
0-250 V @ 15 A
100 A @ 0-5 V
50 A @ 0-10 V
0-250 V @ 15 A
100 A @ 0-5 V
50 A @ 0-10 V
0-250 V @ 15 A
  • RATING : 5 Minutes ON / 15 Minutes OFF. Continuous rating does not exceed 50% of the rated output.
  • METERING : 1) LED digital Ammeter, CT operated for current outputs.
    2) LED digital Voltmeter for voltage output.
    Accuracy : ± 1% ± 3 counts.
  • DIGITAL TIMER : 4 digit, solid state crystal base timer system. Multi range from .0001 to 9999 seconds.
    Accuracy : ± 0.5 % ± 2 counts
  • TIMER CONTROL CIRCUITS : The timer automatically starts when the output is initiated and automatically stops when the device under test operates.
  • START SIGNAL : Internal.
  • STOP SIGNAL : Via-either normally open or normally closed external contacts.
  • AUTO-CUT-OFF : Cuts off output on operation of device under test.
  • OPERATION : Circuit breaker in input, mains on indicator, contractor controlled push buttons for current output on or off, contact mode selector and reset switch.
    ‘SET/TEST’ switch to set up test current level.
  • CONSTRUCTION : Two piece unit. Sheet steel cabinets powder coated and with fold away lifting handles.
  • OPTIONAL ACCESSORIES : 1. Low inductance lead set.
    2. Precision grade (0.5%) Analogue meter with Current transformer.
+ Standard Accessories

Standard Accessories

  • Operating Manual.
  • 2 meter long 3 core mains cable.
  • 2 meter long inter-connecting cable.