Relay Testing Kit RTS-5

Current Injection Testers

Relay Testing Kit RTS-5

Model : RTS-5

Input 240V +-10%, AC, 50/60Hz. Digital Timer 4 digit, solid state, time interval measuring system, 5 ranges from .0001 to 9999 seconds.Accuracy ±0.5% + 1 count. Timer Control Circuits Timer automatically starts when output is initiated and automatically stops when the device. under test operates. Test ConditionsNormally open contacts (Potential free) / Normally closed contacts (Potential Free). Auto cut-offCuts off output on operation of device under test. Duty cycle 10 mins ON / 15 mins OFF. Metering Digital LED volt and amp meters. Accuracy: ± 1% ± 3 digits. Operation A SET / TEST switch is provided so that the appropriate test current can be set up before the test is actually carried out, and to avoid damage to relay coils by disconnecting the test current after the relay has operated. Construction Sheet metal cabinet powder coated with cover and lifting handles. Accessories 3 core mains cord, Test leads-2 metre long and operating manual.

Machine Feature

Input 240V ±10%, AC, 50/60Hz.
Digital Timer 4 digit, solid state, time interval measuring system, 5 ranges from .0001 to 9999 seconds.
Accuracy ±0.5% + 1 count.
Timer Control Circuits Timer automatically starts when output is initiated and automatically stops when the device. under test operates.
Test Conditions Normally open contacts (Potential free) / Normally closed contacts (Potential Free).
Auto cut-off Cuts off output on operation of device under test.
Duty cycle 10 mins ON / 15 mins OFF.
Metering Digital LED volt and amp meters. Accuracy: ± 1% ± 3 digits.
Operation A SET / TEST switch is provided so that the appropriate test current can be set up before the test is actually carried out, and to avoid damage to relay coils by disconnecting the test current after the relay has operated.
Construction Sheet metal cabinet powder coated with cover and lifting handles.
Accessories 3 core mains cord, Test leads-2 metre long and operating manual.

Machine Technical Specification

Output One adjustable output
AC Current 1-2-5-10-20A AC at 4V and 10V
(Open Circuit Voltage)
50-100-200A AC at 4V (Open
Circuit Voltage)
Capacity 600VA
Metering Digital Ammeter : 2-20-200A AC.
Digital Voltmeter : 300V AC.
Accuracy ± 1% ± 3 digits
Voltage AC 0-270V AC, continuously variable
Capacity 500VA
Voltage AC 50V at 2A AC or 110V at 2A AC
Duty Cycle Intermittent
At 10 Volts Continuous up to 10A
5 minutes ON/10 minutes OFF at 20A
At 4 Volts Continuous up to 50A
5 minutes ON/10 minutes OFF at 100A
I minute ON/OFF at 200A
+ Feature

Machine Feature

Input 240V ±10%, AC, 50/60Hz.
Digital Timer 4 digit, solid state, time interval measuring system, 5 ranges from .0001 to 9999 seconds.
Accuracy ±0.5% + 1 count.
Timer Control Circuits Timer automatically starts when output is initiated and automatically stops when the device. under test operates.
Test Conditions Normally open contacts (Potential free) / Normally closed contacts (Potential Free).
Auto cut-off Cuts off output on operation of device under test.
Duty cycle 10 mins ON / 15 mins OFF.
Metering Digital LED volt and amp meters. Accuracy: ± 1% ± 3 digits.
Operation A SET / TEST switch is provided so that the appropriate test current can be set up before the test is actually carried out, and to avoid damage to relay coils by disconnecting the test current after the relay has operated.
Construction Sheet metal cabinet powder coated with cover and lifting handles.
Accessories 3 core mains cord, Test leads-2 metre long and operating manual.
+ Technical Specification

Machine Technical Specification

Output One adjustable output
AC Current 1-2-5-10-20A AC at 4V and 10V
(Open Circuit Voltage)
50-100-200A AC at 4V (Open
Circuit Voltage)
Capacity 600VA
Metering Digital Ammeter : 2-20-200A AC.
Digital Voltmeter : 300V AC.
Accuracy ± 1% ± 3 digits
Voltage AC 0-270V AC, continuously variable
Capacity 500VA
Voltage AC 50V at 2A AC or 110V at 2A AC
Duty Cycle Intermittent
At 10 Volts Continuous up to 10A
5 minutes ON/10 minutes OFF at 20A
At 4 Volts Continuous up to 50A
5 minutes ON/10 minutes OFF at 100A
I minute ON/OFF at 200A