| INPUT POWER SUPPLY |
220 Volts AC, 50 Hz, Mains single phase supply. |
| OUTPUT VOLTAGE |
AC / DC with change of polarity. |
| RATING |
10 minutes ON / 15 minutes OFF. |
| VOLTAGE SOURCE |
Double wound H.T. transformer and half wave silicon rectifiers. |
| OUTPUT CONTROL |
Continuously variable manual operation. |
| ZERO INTERLOCKING |
Zero - start interlocking for H.V. output. |
| METERING |
1) Analogue, linear scaled, KV meter, to read DC and AC output
voltage.
Accuracy : with in + 4% of full scale value. |
| |
2) Analogue, linear scaled, mA meter, to read DC and AC
leakage current.
Accuracy : with in + 4% of full scale value. |
| INDICATION (Failure) |
Buzzer and lamp to indicate breakdown failure. |
| PROTECTION |
Fused input, a fast acting D.C. Relay cuts the H.V., when
current exceeds the trip value. |
| AUXILLARIES |
Mains ON/OFF switch, Fuse, AC/DC selector,
H.V: ON and H.V. OFF push buttons to energize contractor for
circuit protection.
: INDICATOR LAMPS:
: MAINS ON: Green.
: H.T. OFF: Yellow.
: H.T. ON: Red
: Breakdown: Red/Amber |
| CONSTRUCTION |
Two unit sets: Control unit and High voltage unit with rectifier. |
| ACCESSORIES |
| :
1) Mains cord 2 meter long |
1 Number. |
| : 2) output leads with alligator clips at
one end |
1 pair. (2 meter long ) |
| : 3) operating manual |
2 Numbers. |
|