Timer Interval Meter

Timer Interval Meters

Timer Interval Meter

Model : TIM-1

The UDEY TIM-1 is a high precision, new generation test set using crystal base for measurements.

Machine Feature

  • Digital display in 4 digits.
  • Multi-range: to 9999 seconds in five ranges
  • Portable light weight.

Machine Technical Specification

Power Supply 230V ± 10%, AC 50 Hz
Measuring Range 9999/9.999/99.99/999.9/9999 seconds
Measuring Accuracy Range: ±0.05% ± 1 count
Display LED 12.5 mm; 4 digit with decimal
Protection of Input Signal up to 240V AC / DC
In Contacts [Potential Free] OPEN: 100K or more
CLOSED: 100 ohm or less
Auxiliary output contact 1 change over potential free.
Rating 1A 240V AQC or 24V DC.
Operating Modes Time interval measurement; stop watch.
1) Start/Stop by potential free open contact closing
2) Start/Stop by potential free close contact Opening
3) Starts by step +ve voltage application (50-250V DC)
4) Stops by step +ve voltage removal (50-250V DC)
Usage Environment : Less than 45°C.
Less than 85% R.H.
Enclosure ABS body with tilting handle.
Dimensions : 21.5 (W)x23(D)x9(H) cm approx.
Weight : 1.8 kg approx.

Standard Accessories

  • Power Supply cord 3 core.
  • Flexible testing cable set with alligator clamps-2 pairs.
  • Operating Manual.
+ Feature

Machine Feature

  • Digital display in 4 digits.
  • Multi-range: to 9999 seconds in five ranges
  • Portable light weight.
+ Technical Specification

Machine Technical Specification

Power Supply 230V ± 10%, AC 50 Hz
Measuring Range 9999/9.999/99.99/999.9/9999 seconds
Measuring Accuracy Range: ±0.05% ± 1 count
Display LED 12.5 mm; 4 digit with decimal
Protection of Input Signal up to 240V AC / DC
In Contacts [Potential Free] OPEN: 100K or more
CLOSED: 100 ohm or less
Auxiliary output contact 1 change over potential free.
Rating 1A 240V AQC or 24V DC.
Operating Modes Time interval measurement; stop watch.
1) Start/Stop by potential free open contact closing
2) Start/Stop by potential free close contact Opening
3) Starts by step +ve voltage application (50-250V DC)
4) Stops by step +ve voltage removal (50-250V DC)
Usage Environment : Less than 45°C.
Less than 85% R.H.
Enclosure ABS body with tilting handle.
Dimensions : 21.5 (W)x23(D)x9(H) cm approx.
Weight : 1.8 kg approx.
+ Standard Accessories

Standard Accessories

  • Power Supply cord 3 core.
  • Flexible testing cable set with alligator clamps-2 pairs.
  • Operating Manual.

Video