Relay Testing Kit RTS-50
Model : RTS-50
Input 240V ±10%, AC, 50/60Hz. Digital Timer 4 digit, solid state, time interval measuring system, 5 ranges from .0001 to 9999 seconds.Accuracy ±0.5% + 1 count. Timer Control Circuits Timer automatically starts when output is initiated and automatically stops when the device. under test operates. Test ConditionsNormally open contacts (Potential free) / Normally closed contacts (Potential Free). Auto cut-offCuts off output on operation of device under test. Duty cycle 10 mins ON / 15 mins OFF. Metering Digital LED volt and amp meters. Accuracy: ± 1% ± 3 digits. Operation A SET / TEST switch is provided so that the appropriate test current can be set up before the test is actually carried out, and to avoid damage to relay coils by disconnecting the test current after the relay has operated. Construction Sheet metal cabinet powder coated with cover and lifting handles. Accessories 3 core mains cord, Test leads-2 metre long and operating manual.
Machine Feature
Input 240V ±10%, AC, 50/60Hz. Digital Timer 4 digit, solid state, time interval measuring system, 5 ranges from .0001 to 9999 seconds. Accuracy ±0.5% + 1 count. Timer Control Circuits Timer automatically starts when output is initiated and automatically stops when the device. under test operates. Test ConditionsNormally open contacts (Potential free) / Normally closed contacts (Potential Free). Auto cut-offCuts off output on operation of device under test. Duty cycle 10 mins ON / 15 mins OFF. Metering Digital LED volt and amp meters. Accuracy: ± 1% ± 3 digits. Operation A SET / TEST switch is provided so that the appropriate test current can be set up before the test is actually carried out, and to avoid damage to relay coils by disconnecting the test current after the relay has operated. Construction Sheet metal cabinet powder coated with cover and lifting handles. Accessories 3 core mains cord, Test leads-2 metre long and operating manual.
Machine Technical Specification
Output | Two independently adjustable outputs available simultaneously |
---|---|
AC Current | 0 – 50A at 20V AC 0 – 25A at 40V AC 0 – 5A at 150V AC 0 – 1A at 250V AC Each of these outputs has a separate terminal referred to one common terminal. |
Voltage | 0-220V, 1A, DC continuously adjustable, non-floating output 0-250V, 1A, AC continuously adjustable, fully floating auxiliary outputEach of these outputs has a separate pair of terminals. |
Metering | Current/Voltage: Digital 12.5mm LED meters |
Current | Current Displays output in Amperes 0-2-20-50A, |
Accuracy | ± 1% ± 5 digits |
Voltage | Separate meters for AC and DC outputs 3-digit range, 300V |
Accuracy | 0.5% 2 digits |
- + Feature
Machine Feature
Input 240V ±10%, AC, 50/60Hz. Digital Timer 4 digit, solid state, time interval measuring system, 5 ranges from .0001 to 9999 seconds. Accuracy ±0.5% + 1 count. Timer Control Circuits Timer automatically starts when output is initiated and automatically stops when the device. under test operates. Test ConditionsNormally open contacts (Potential free) / Normally closed contacts (Potential Free). Auto cut-offCuts off output on operation of device under test. Duty cycle 10 mins ON / 15 mins OFF. Metering Digital LED volt and amp meters. Accuracy: ± 1% ± 3 digits. Operation A SET / TEST switch is provided so that the appropriate test current can be set up before the test is actually carried out, and to avoid damage to relay coils by disconnecting the test current after the relay has operated. Construction Sheet metal cabinet powder coated with cover and lifting handles. Accessories 3 core mains cord, Test leads-2 metre long and operating manual.
- + Technical Specification
Machine Technical Specification
Output Two independently adjustable
outputs available simultaneouslyAC Current 0 – 50A at 20V AC
0 – 25A at 40V AC
0 – 5A at 150V AC
0 – 1A at 250V AC
Each of these outputs has a separate terminal referred to one common terminal.Voltage 0-220V, 1A, DC continuously
adjustable, non-floating output
0-250V, 1A, AC continuously
adjustable, fully floating auxiliary outputEach of these outputs has a separate pair of terminals.Metering Current/Voltage: Digital 12.5mm LED meters Current Current Displays output in Amperes 0-2-20-50A, Accuracy ± 1% ± 5 digits Voltage Separate meters for AC and DC outputs
3-digit range, 300VAccuracy 0.5% 2 digits