US, A, AD Series
Model : US/7, US/8, US/10, A/7, A/8, A/10
Insulating Oil Testers are designed for the easy and accurate determination of the die-electric strength of insulating oils used in transformers, switchgears, bushings, capacitors and other electrical apparatus. They are ideal for on-site field and laboratory use. Safe and easy operation has made UDEY insulating oil testers the industry standard for more than 55 years.
Machine Feature
• Confirms to IS 6792, IEC 156
• Tests insulating oils to IS, IEC, ASTM, etc.
• Test voltage to 100kV
• Motorized rise of test voltage: 2kV/sec
• One piece construction with safety interlocked transparent hood covering test cell
• Test voltage can be held at any desired level
• kV meter continues to indicate breakdown voltage even after breakdown
• Light weight: 36 kg only
• Portable, rugged and with cover.
Machine Technical Specification
Model | Display kV | Output kV | Voltage Rise | Dimensions LBH cms. | Weight Kgs Apx. |
---|---|---|---|---|---|
US/6 | Analog | 60 | Manual | 43 x 47 x 40 | 36 |
US/7 | Analog | 75 | Manual | 43 x 47 x 40 | 39 |
US/8 | Analog | 80 | Manual | 43 x 47 x 40 | 39 |
US/10 | Analog | 100 | Manual | 43 x 47 x 40 | 40 |
A/6 | Analog | 60 | Motorized | 43 x 47 x 40 | 36 |
A/7 | Analog | 75 | Motorized | 43 x 47 x 40 | 39 |
A/8 | Analog | 80 | Motorized | 43 x 47 x 40 | 39 |
A/10 | Analog | 100 | Motorized | 43 x 47 x 40 | 40 |
AD/6 | Digital | 60 | Motorized | 43 x 47 x 40 | 36 |
AD/7 | Digital | 75 | Motorized | 43 x 47 x 40 | 39 |
AD/8 | Digital | 80 | Motorized | 43 x 47 x 40 | 39 |
AD/10 | Digital | 100 | Motorized | 43 x 47 x 40 | 40 |
Standard Accessories
1. Mains cord, 2 meter long.
2. Test cell TC-2 with electrodes.
3. GO & NOGO gauges.
4. Operating Manual.
- + Feature
Machine Feature
• Confirms to IS 6792, IEC 156
• Tests insulating oils to IS, IEC, ASTM, etc.
• Test voltage to 100kV
• Motorized rise of test voltage: 2kV/sec
• One piece construction with safety interlocked transparent hood covering test cell
• Test voltage can be held at any desired level
• kV meter continues to indicate breakdown voltage even after breakdown
• Light weight: 36 kg only
• Portable, rugged and with cover.- + Technical Specification
Machine Technical Specification
Model Display kV Output kV Voltage Rise Dimensions LBH cms. Weight Kgs Apx. US/6 Analog 60 Manual 43 x 47 x 40 36 US/7 Analog 75 Manual 43 x 47 x 40 39 US/8 Analog 80 Manual 43 x 47 x 40 39 US/10 Analog 100 Manual 43 x 47 x 40 40 A/6 Analog 60 Motorized 43 x 47 x 40 36 A/7 Analog 75 Motorized 43 x 47 x 40 39 A/8 Analog 80 Motorized 43 x 47 x 40 39 A/10 Analog 100 Motorized 43 x 47 x 40 40 AD/6 Digital 60 Motorized 43 x 47 x 40 36 AD/7 Digital 75 Motorized 43 x 47 x 40 39 AD/8 Digital 80 Motorized 43 x 47 x 40 39 AD/10 Digital 100 Motorized 43 x 47 x 40 40 - + Standard Accessories
Standard Accessories
1. Mains cord, 2 meter long.
2. Test cell TC-2 with electrodes.
3. GO & NOGO gauges.
4. Operating Manual.
Transformer Oil Testing
The transformer oil test kit is ensured to measure with high level of accuracy. Since the transformer oils are designed to insulate electrically, they must be periodically tested for stability by using standard testing procedures. The testing of transformer oil works by acquiring the breakdown voltage. The RMS value of the breakdown voltage is reported as a result. This process is very safe. A transparent hood covers the test cell to ensure extended and further operator safety level.
The transformer oil testing kit is of light weight and it is portable, so mobility of the transformer oil test kit is not an issue at all. The testing voltage can be set to anywhere up to 100 Kilo Voltage. The transformer oil test kit comes with an operating manual for guiding users, a 2 meter long main cord, GO and NO GO gauges, in addition to a test cell. Several oils are able to be tested with this specific kit including IS and IEC oils. All of the features of this machine and the transformer oil test kit make the testing of transformer oil practical and ideal, that’s what makes UDEYRAJ the top company that it is.