5 kV AC Hipot
Model : US-5-100
UDEY AC HIPOT TESTERS-US SERIES are AC High voltage break down / withstand voltage testers with digital displays, count-down timer and set trip current facility. These are accurate, durable instruments designed to perform high voltage withstand / breakdown tests on various types of electrical / electronic products, systems and components.
Machine Feature
• Digital readouts of test voltage, leakage current and time
• Multi-range mA meter
• Timer count-down digital display
• Digital display to set trip current
• ‘HV ON’ and “FAIL’ indicators
• Panel with legend for controls
• Optional HV gun for output
• Rugged table top cabinet Safety
All metal cabinet
High quality double wound HV transformer
Good quality components and hardware
Extra EARTH Post Provided
Machine Technical Specification
Supply Voltage | 230 Volts ± 10%AC, 50 Hz single Phase. |
---|---|
Output Voltage | 0-5kV AC, 50Hz. |
Output control | One knob manual control, continuously variable through torodial auto transformer. |
Output Current | 2-20-100 mA. |
Trip Current: Settable | 3 ranges: 0.1-2mA; 0.1-20mA; 0.1-100mA |
Indicators | Lamps to indicate ‘HV ON’, ‘FAIL’. |
Alarms | Range: 0.1-5.00 kV Display: LED digital 3 digits Resolution: 0.01 kV Accuracy: ± 3% + 4 digits |
kV Meter | Range: 0-2mA; 2-20mA and 20-100 mA Display: LED digital 3.5 digits Resolution: 2mA range: 1uA : 20mA range: 10uA : 100mA range: 100uA Accuracy: ± 3% + 4 digits |
Timer | Settable : Thumbwheel switch:1-99 seconds Display: LED Digital 2 digits, countdown. Resolution: 1 second Accuracy: ± 5% |
Duty Cycle | 15 minutes ON / 15 minutes OFF. |
Dimensions | 38 x 28 x 19 cm; |
Weight | 15 kg |
Shipping Dimensions | 43 x 33 x 24 cm; |
Shipping Weight | 18 kg |
Standard Accessories
a) Mains cord 2 meter long: 1 Number.
b) HV test leads 1 meter long: 1 Set.
- + Feature
Machine Feature
• Digital readouts of test voltage, leakage current and time
• Multi-range mA meter
• Timer count-down digital display
• Digital display to set trip current
• ‘HV ON’ and “FAIL’ indicators
• Panel with legend for controls
• Optional HV gun for output
• Rugged table top cabinet Safety
All metal cabinet
High quality double wound HV transformer
Good quality components and hardware
Extra EARTH Post Provided- + Technical Specification
Machine Technical Specification
Supply Voltage 230 Volts ± 10%AC, 50 Hz single Phase. Output Voltage 0-5kV AC, 50Hz. Output control One knob manual control, continuously variable through
torodial auto transformer.Output Current 2-20-100 mA. Trip Current: Settable 3 ranges: 0.1-2mA; 0.1-20mA; 0.1-100mA Indicators Lamps to indicate ‘HV ON’, ‘FAIL’. Alarms Range: 0.1-5.00 kV
Display: LED digital 3 digits
Resolution: 0.01 kV
Accuracy: ± 3% + 4 digitskV Meter Range: 0-2mA; 2-20mA and 20-100 mA
Display: LED digital 3.5 digits
Resolution: 2mA range: 1uA
: 20mA range: 10uA
: 100mA range: 100uA
Accuracy: ± 3% + 4 digitsTimer Settable : Thumbwheel switch:1-99 seconds
Display: LED Digital 2 digits, countdown.
Resolution: 1 second
Accuracy: ± 5%Duty Cycle 15 minutes ON / 15 minutes OFF. Dimensions 38 x 28 x 19 cm; Weight 15 kg Shipping Dimensions 43 x 33 x 24 cm; Shipping Weight 18 kg - + Standard Accessories
Standard Accessories
a) Mains cord 2 meter long: 1 Number.
b) HV test leads 1 meter long: 1 Set.