DC Hipot Testers DPC series
Model : DPC-60-5 DPC-80-5 DPC-120-5
DPC series hipots are used for proof testing of high voltage equipment in power engineering. Routine testing of the insulation and leakage is a necessary requirement for electrical equipments. Other areas include: Cable breakdown testing, capacitor charging and general laboratory use.
Machine Feature
Portable: 60kV-5mA; only 10kg. Over voltage protection setting. Digital readout of test voltage & leakage current. Optional Extra mA meter to measure leakage in HT. Aluminum alloy cabinet with cover with handle.
Easy to carry as small dimension and low weight.
Machine Technical Specification
Supply Power | 230V AC + /- 10%, 50 Hz. |
---|---|
Output Voltage | As per model |
Output Current | As per model |
Ripple Factor | < 3% |
Trim mA | 1 to 1.1 times rated current |
Rating | Intermittent [15 min ON/OFF] |
Accuracy HT setting | <1.5% |
Meters | Digital display: kV and mA |
Measurement accuracy | 3% max + /- 2 digits |
Environment Termparature | 45 C max |
Stirrer | Automatic (60 Seconds). |
Timer | Automatic (60 Seconds). |
Enclosure | Aluminium metal cabinet with cover and lifting handles. |
Ralative Humidity | Non-condensing: 80% max |
Cabinet | Aluminum cabinet with handle |
Model | DPC-60-5 | DPC-80-5 | DPC-120-5 |
---|---|---|---|
Voltage Output | 0-60kV DC | 0-80kV DC | 0-120kV DC |
Current output | 5mA | 5mA | 5mA |
Trip level | 5 to 5.5mA | Control+HT unit | Control+HT unit |
Construction | Control+HT unit | 5 to 5.5mA | 5 to 5.5mA |
Dimensions cm : app. | CU : 39 x 28 x 25 HT : 57 x 20 x 23 | CU : 39 x 28 x 25 HT : 81 x 25 x 25 | CU : 39 x 28 x 25 HT : 81 x 25 x 25 |
Weight kg app. | CU:6 HT:4 | CU:8 HT:10 | CU:8 HT:10 |
Standard Accessories
Molded mains cord – 1No.
HV Test leads for 60 kV model only – 1No.
Earth cable, 4 meter long – 1No.
Discharge rod – 1No.
- + Feature
Machine Feature
Portable: 60kV-5mA; only 10kg. Over voltage protection setting. Digital readout of test voltage & leakage current. Optional Extra mA meter to measure leakage in HT. Aluminum alloy cabinet with cover with handle.
Easy to carry as small dimension and low weight.- + Technical Specification
Machine Technical Specification
Supply Power 230V AC + /- 10%, 50 Hz. Output Voltage As per model Output Current As per model Ripple Factor < 3% Trim mA 1 to 1.1 times rated current Rating Intermittent [15 min ON/OFF] Accuracy HT setting <1.5% Meters Digital display: kV and mA Measurement accuracy 3% max + /- 2 digits Environment Termparature 45 C max Stirrer Automatic (60 Seconds). Timer Automatic (60 Seconds). Enclosure Aluminium metal cabinet with cover and lifting handles. Ralative Humidity Non-condensing: 80% max Cabinet Aluminum cabinet with handle Model DPC-60-5 DPC-80-5 DPC-120-5 Voltage Output 0-60kV DC 0-80kV DC 0-120kV DC Current output 5mA 5mA 5mA Trip level 5 to 5.5mA Control+HT unit Control+HT unit Construction Control+HT unit 5 to 5.5mA 5 to 5.5mA Dimensions
cm : app.CU : 39 x 28 x 25
HT : 57 x 20 x 23CU : 39 x 28 x 25
HT : 81 x 25 x 25CU : 39 x 28 x 25
HT : 81 x 25 x 25Weight kg app. CU:6 HT:4 CU:8 HT:10 CU:8 HT:10 - + Standard Accessories
Standard Accessories
Molded mains cord – 1No.
HV Test leads for 60 kV model only – 1No.
Earth cable, 4 meter long – 1No.
Discharge rod – 1No.