AC, DC, AC and DC Hipot

HIPOTS (High Voltage Testers)

AC, DC, AC and DC Hipot

Model

UDEY H.V. testers are specifically designed for safe and accurate measurement of leakage current to evaluate insulation integrity. These testers are portable, one end ground test systems, ideal for H.V. testing. Accurate leakage measurements are ensured by placing the current meter in the return of the H.V. path. Many features which UDEY provides as standard are either offered by competitors as optional features or not at all. Years of Design, engineering and manufacturing experience have made UDEY H.V. testers the most durable, easily operated and the best designed sets in the industry.

Machine Feature

• Panel mounted controls & indicators with easy to read legend.
• Continuously variable output from zero to full voltage.
• Low end ground test.
• Multi range analogue kV meter and current meter.
• Fast acting overload circuit breaker.
• Zero start interlock.

Machine Technical Specification

NPUT220 Volts ± 10 %, 50/60 HZ AC single phase.
RATING100 % – 10 minutes and 50 % – continuous.
METERINGAnalogue, linear scaled moving coil meters of 96 mm square.
kV meter : Two ranges
mA meter : Two ranges
Accuracy of measurement : ± 4 % of full scale.
TRIP20% to 100% of rating adjustable.
OUTPUT CONTROLOne knob manual control.
COOLINGAir cooled epoxy resin cast up to 50 kV and oil cooled for 75 kV and above.
CONSTRUCTIONSheet steel cabinets powder coated.
Up to 30 kV : Single unit witd lifting handles and rubber legs.
50 kV and above : Two unit on wheels.
AC H V TESTERSDC H V TESTERS
ModelOutput: 50 HZModelOutput: Peak value
HJ-5-500-5kV / 50mAHPD-3-200-3kV / 20mA
HT-10-1000-10kV / 100mAHPD-5-200-5kV / 20mA
HT-20-1000-20kV / 100mAHPD-10-200-10kV / 20mA
HT-30-1000-30kV / 100mAHPD-20-200-20kV / 20mA
HT-50-1000-50kV / 100mAHPD-30-200-30kV / 20mA
HT-75-1000-75kV / 100mAHPD-50-200-50kV / 20mA
HT-100-1000-100kV / 100mAHPD-75-200-75kV / 20mA
AC & DC H V TESTERS
ModelOutput-DC(peak Value)Output-AC(50 Hz)
HPACD-50-5kV / 10mA0-5kV / 10mA
HPACD-100-10kV / 10mA0-10kV / 10mA
HPACD-200-20kV / 10mA0-15kV / 10mA
HPACD-300-30kV / 10mA0-20kV / 20mA
HPACD-500-50kV / 6mA0-35kV / 12mA
HPACD-750-75kV / 5mA0-50kV / 10mA
Testers with higher output capacity also manufactured.
+ Feature

Machine Feature

• Panel mounted controls & indicators with easy to read legend.
• Continuously variable output from zero to full voltage.
• Low end ground test.
• Multi range analogue kV meter and current meter.
• Fast acting overload circuit breaker.
• Zero start interlock.

+ Technical Specification

Machine Technical Specification

NPUT220 Volts ± 10 %, 50/60 HZ AC single phase.
RATING100 % – 10 minutes and 50 % – continuous.
METERINGAnalogue, linear scaled moving coil meters of 96 mm square.
kV meter : Two ranges
mA meter : Two ranges
Accuracy of measurement : ± 4 % of full scale.
TRIP20% to 100% of rating adjustable.
OUTPUT CONTROLOne knob manual control.
COOLINGAir cooled epoxy resin cast up to 50 kV and oil cooled for 75 kV and above.
CONSTRUCTIONSheet steel cabinets powder coated.
Up to 30 kV : Single unit witd lifting handles and rubber legs.
50 kV and above : Two unit on wheels.
AC H V TESTERSDC H V TESTERS
ModelOutput: 50 HZModelOutput: Peak value
HJ-5-500-5kV / 50mAHPD-3-200-3kV / 20mA
HT-10-1000-10kV / 100mAHPD-5-200-5kV / 20mA
HT-20-1000-20kV / 100mAHPD-10-200-10kV / 20mA
HT-30-1000-30kV / 100mAHPD-20-200-20kV / 20mA
HT-50-1000-50kV / 100mAHPD-30-200-30kV / 20mA
HT-75-1000-75kV / 100mAHPD-50-200-50kV / 20mA
HT-100-1000-100kV / 100mAHPD-75-200-75kV / 20mA
AC & DC H V TESTERS
ModelOutput-DC(peak Value)Output-AC(50 Hz)
HPACD-50-5kV / 10mA0-5kV / 10mA
HPACD-100-10kV / 10mA0-10kV / 10mA
HPACD-200-20kV / 10mA0-15kV / 10mA
HPACD-300-30kV / 10mA0-20kV / 20mA
HPACD-500-50kV / 6mA0-35kV / 12mA
HPACD-750-75kV / 5mA0-50kV / 10mA
Testers with higher output capacity also manufactured.