UDH-50-10-T

Insulation Resistance Testers

Insulation Resistance Tester

Model : UDH-50-10-T

Machine Features

  • Automatic-microcontroller operated
  • Test voltages: 0.5kV, 1kV, 2.5kV, 5kV
  • Resistance range to 10TΩ
  • Continuous digital display on LCM with bar graph
  • Test modes: Insulation resistance, PI (Polarization Index), AR (Dielectric Absorption Ratio), (PI and AR automatically calculated)
  • High charging circuit: >3mA
  • Data storage-250 sets of results, data recall and real time + calendar data
  • Backlit LCM with status and battery condition display
  • Power source: Internal re-chargeable battery / AC mains

Main Features

  • Advanced MCP technology
  • Tests: IR; AR [DAR]; PI
  • Test Voltages: 0.5-1-2.5-5 kV DC
  • Insulation range up to 10 Tera Ohms
  • Large LCM (back lit)
  • Built in rechargeable lithium battery

Standards

  • Instrument to IS : 10656 / IS : 11994
  • Safety Standard to IEC 61010-1

Machine Technical Specification

Test Voltage0.5 / 1 / 2.5 / 5 kV DC
Voltage accuracy+/- 5% of rated value
I R range1 Mohm to 10 Tera ohm
I R accuracy1MΩ-10MΩ :+/-10%rdg +/-3 dgt
10MΩ-10GΩ :+/-5%rdg +/-3 dgt
20GΩ-200GΩ :+/-10%rdg +/-3 dgt
200GΩ-10TΩ :+/-20%rdg
Test SequenceInsulation resistance (IR)
Absorption ratio (DAR)
Polarization ratio (PI)
FunctionsTest, save, recall,
Discharge ratefrom 5000V to 50V: < 250 ms / uF
Power sourceInternal rechargeable lithium battery
FunctionsTest, save, recall,
Ambient5-40 deg C / RH= max 70%
EnclosureStrong molded cabinet with cover
Dimensions28 x 21 x 10 cm approximate
Weight2.5 kg approximate

Accessories

  • Test leads 2 meter long : 3 pcs
  • Battery charger : 1 pc
  • Works test certificate : 1 pc
  • Operating manual : 1 pc

Optional Accessories

  • Test leads 10 meter long : 3 pcs
  • Calibration resistance
  • 200 Meg ohm 5 kV : 2%
  • 500 Meg ohm 5 kV : 2%
  • 10 Giga ohm 5 kV : 2%
  • Aluminum carry box
+ Feature

Machine Features

  • Automatic-microcontroller operated
  • Test voltages: 0.5kV, 1kV, 2.5kV, 5kV
  • Resistance range to 10TΩ
  • Continuous digital display on LCM with bar graph
  • Test modes: Insulation resistance, PI (Polarization Index), AR (Dielectric Absorption Ratio), (PI and AR automatically calculated)
  • High charging circuit: >3mA
  • Data storage-250 sets of results, data recall and real time + calendar data
  • Backlit LCM with status and battery condition display
  • Power source: Internal re-chargeable battery / AC mains

Main Features

  • Advanced MCP technology
  • Tests: IR; AR [DAR]; PI
  • Test Voltages: 0.5-1-2.5-5 kV DC
  • Insulation range up to 10 Tera Ohms
  • Large LCM (back lit)
  • Built in rechargeable lithium battery

Standards

  • Instrument to IS : 10656 / IS : 11994
  • Safety Standard to IEC 61010-1
+ Technical Specification

Machine Technical Specification

Test Voltage0.5 / 1 / 2.5 / 5 kV DC
Voltage accuracy+/- 5% of rated value
I R range1 Mohm to 10 Tera ohm
I R accuracy1MΩ-10MΩ :+/-10%rdg +/-3 dgt
10MΩ-10GΩ :+/-5%rdg +/-3 dgt
20GΩ-200GΩ :+/-10%rdg +/-3 dgt
200GΩ-10TΩ :+/-20%rdg
Test SequenceInsulation resistance (IR)
Absorption ratio (DAR)
Polarization ratio (PI)
FunctionsTest, save, recall,
Discharge ratefrom 5000V to 50V: < 250 ms / uF
Power sourceInternal rechargeable lithium battery
FunctionsTest, save, recall,
Ambient5-40 deg C / RH= max 70%
EnclosureStrong molded cabinet with cover
Dimensions28 x 21 x 10 cm approximate
Weight2.5 kg approximate
+ Standard Accessories

Accessories

  • Test leads 2 meter long : 3 pcs
  • Battery charger : 1 pc
  • Works test certificate : 1 pc
  • Operating manual : 1 pc

Optional Accessories

  • Test leads 10 meter long : 3 pcs
  • Calibration resistance
  • 200 Meg ohm 5 kV : 2%
  • 500 Meg ohm 5 kV : 2%
  • 10 Giga ohm 5 kV : 2%
  • Aluminum carry box
STILL NOT SURE WHAT TO DO?

We are glad that you preferred to contact us. Please fill our short form and one of our friendly team members will contact you back.

    X
    CONTACT US